Shakespeare Electronic SE500 Spezifikationen Seite 44

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 58
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 43
CC1000
SWRS048A Page 44 of 55
MODEM2 Register (0Fh)
REGISTER NAME Default
value
Active Description
MODEM2[7] PEAKDETECT 1 H Peak Detector and Remover disabled or
enabled
0 : Peak detector and remover is
disabled
1 : Peak detector and remover is
enabled
MODEM2[6:0] PEAK_LEVEL_OFFSET[6:0] 0010110 - Threshold level for Peak Remover in
Demodulator. Correlated to frequency
deviation, see note.
Note: PEAK_LEVEL_OFFSET[6:0] =
8
5
2
+
f
IF
Fs
IF
Fs
low
low
where
1_
_
+
=
FREQXOSC
xoscf
Fs
and
accuracyXTALrffkHzIF
low
__2150
=
and f is the separation
MODEM1 Register (10h)
REGISTER NAME Default
value
Active Description
MODEM1[7:5] MLIMIT 011 - Sets the limit for the Manchester Violation Flag.
A Manchester Value = 14 is a perfect bit and a
Manchester Value = 0 is a constant level (an
unbalanced corrupted bit)
000 : No Violation Flag is set
001 : Violation Flag is set for Manchester Value < 1
010 : Violation Flag is set for Manchester Value < 2
011 : Violation Flag is set for Manchester Value < 3
100 : Violation Flag is set for Manchester Value < 4
101 : Violation Flag is set for Manchester Value < 5
110 : Violation Flag is set for Manchester Value < 6
111 : Violation Flag is set for Manchester Value < 7
MODEM1[4] LOCK_AVG_IN 0 H Lock control bit of Average Filter
0 : Average Filter is free-running
1 : Average Filter is locked
MODEM1[3] LOCK_AVG_MODE 0 - Automatic lock of Average Filter
0 : Lock of Average Filter is controlled automatically
1 : Lock of Average Filter is controlled by
LOCK_AVG_IN
MODEM1[2:1] SETTLING[1:0] 11 - Settling Time of Average Filter
00 : 11 baud settling time, worst case 1.2dB loss in
sensitivity
01 : 22 baud settling time, worst case 0.6dB loss in
sensitivity
10 : 43 baud settling time, worst case 0.3dB loss in
sensitivity
11 : 86 baud settling time, worst case 0.15dB loss in
sensitivity
MODEM1[0] MODEM_RESET_N 1 L Separate reset of MODEM
Seitenansicht 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 57 58

Kommentare zu diesen Handbüchern

Keine Kommentare